Dwelling Space Standards - SUMMARY

 0    42 flashcards    sim
mp3 indir Baskı oynamak kendini kontrol et
 
soru cevap
Dwelling Space Standards
Single storey dwelling (4 bed 6 person = 99sq.m) Two storey dwelling (4 bed 6 person = 107sq.m) Three storey dwelling (4 bed 6 person = 113sq.m)
öğrenmeye başla
Standardy Mieszkaniowych standartów
gross internal area
For dwellings designed for more than 6 people, at least 10sq.m. gross internal area should be provided for each additional person.
öğrenmeye başla
Powierzchnia wewnętrzna brutto
accommodate
Dwelling plans should demonstrate that dwellings will accommodate the furniture, access and activity space requirements relating to the declared level of occupancy.
öğrenmeye başla
pomieścić
Circulation in the home
The minimum width of hallways and other circulation spaces inside the home should be 900mm. This may reduce to 750mm
öğrenmeye başla
Krążenie w domu
doorway
Minimum clear opening width of doorway (mm) = 750
öğrenmeye başla
wejście
Living / dining / kitchen
The following combined floor areas for living / kitchen / dining space should be met: 2 person = 23sq.m. 3 person = 25sq.m. 4 person= 27sq.m. 5 person= 29sq.m. 6 person= 31sq.m.
öğrenmeye başla
Salon / jadalnia / kuchnia
occupancy
Designed level of occupancy
öğrenmeye başla
ilość osób
sitting area
The minimum width of the main sitting area should be 2.8m in 2-3 person dwellings and 3.2m in dwellings designed for four or more people.
öğrenmeye başla
miejsce do siedzenia
three or more bedrooms
Dwellings with three or more bedrooms should have two living spaces, for example a living room and a kitchen-dining room. Both rooms should have external windows.
öğrenmeye başla
trzy lub więcej sypialni
three or more bedrooms
Both rooms should have external windows. If a kitchen is adjacent to the living room, the internal partition between the rooms should not be load-bearing, to allow for reconfiguration as an open plan arrangement.
öğrenmeye başla
trzy lub więcej sypialni
adjacent to
öğrenmeye başla
przylegający
load-bearing wall
the internal partition between the rooms should not be load-bearing, to allow for reconfiguration as an open plan arrangement.
öğrenmeye başla
ściana nośna
wheelchair
There should be space for turning a wheelchair in dining areas and living rooms and basic circulation space for wheelchairs elsewhere
öğrenmeye başla
wózek inwalidzki
entrance level
A living room, living space or kitchen dining room should be at entrance level
öğrenmeye başla
Poziom wejściowy
Bedrooms AREA
The minimum area of a single bedroom should be 8 sq m. The minimum area of a double or twin bedroom should be 12 sq m.
öğrenmeye başla
OBSZAR sypialnie
Bedrooms WIDTH
The minimum width of double and twin bedrooms should be 2.75m in most of the length of the room.
öğrenmeye başla
Sypialnie Szerokość
convenient temporary bed space
In homes of two or more storeys with no permanent bedroom at entrance level=, there should be space on the entrance level that could be used as a convenient temporary bed space
öğrenmeye başla
wygodna tymczasowa sypialnia
ceiling hoist
Structure above a main bedroom and an accessible bathroom should be capable of supporting a ceiling hoist and the design should allow for a reasonable route between this bedroom and bathroom
öğrenmeye başla
podnośnik sufitowy
hoist
öğrenmeye başla
podnośnik
Bathrooms and WCs
Dwellings designed for an occupancy of five or more people should provide a minimum of one bathroom with WC and one additional WC.
öğrenmeye başla
Łazienki i toalety
Bathrooms and WCs
Where there is no accessible bathroom at entrance level=, a wheelchair accessible WC with potential for a shower to be installed should be provided at entrance level
öğrenmeye başla
Łazienki i toalety
Private open space
A minimum of 5 sq m of private outdoor space should be provided for 1-2 person dwellings and an extra 1 sq m should be provided for each additional occupant.
öğrenmeye başla
Prywatna otwarta przestrzeń
balconies
The minimum depth and width of all balconies and other private external spaces is 1500mm.
öğrenmeye başla
balkony
habitable
the designer should demonstrate how good levels of ventilation, daylight and privacy will be achieved in each habitable room and the kitchen.
öğrenmeye başla
mieszkalny
Floor to ceiling heights
The minimum floor to ceiling height in habitable rooms is 2.5m between finished floor level and finished ceiling level.
öğrenmeye başla
Wysokość od podłogi do sufitu
desirable
A minimum floor to ceiling height of 2.6m in habitable rooms is considered desirable
öğrenmeye başla
pożądany
encouraged to do something
taller ceiling heights are encouraged in ground floor dwellings.
öğrenmeye başla
zachęca do zrobienia czegoś
Daylight and sunlight
Glazing to all habitable rooms should be not less than 20% of the internal floor area of the room.
öğrenmeye başla
Światło i słońce
stair providing easy access
In the Lifetime Homes Criteria a stair providing easy access is defined as one having maximum risers of 170mm, minimum goings of 250mm and a minimum width of 900mm measured 450mm above the pitch line.
öğrenmeye başla
schody zapewnia łatwy dostęp
double loaded
double loaded (they serve dwellings on each side)
öğrenmeye başla
podwójnie obciążony
Entrance and approach
All main entrances to houses, ground floor flats and communal entrance lobbies should be visible from the public realm and clearly identified.
öğrenmeye başla
Wejście i podejście
communal entrance lobbies
öğrenmeye başla
komunalne hole wejściowe
public realm
All main entrances to houses, ground floor flats and communal entrance lobbies should be visible from the public realm and clearly identified.
öğrenmeye başla
sfera publiczna
gently sloping
The approach to all entrances should preferably be level or gently sloping
öğrenmeye başla
łagodnie opadający
be level
The approach to all entrances should preferably be level or gently sloping
öğrenmeye başla
być na poziomie
illuminated
All entrances should be illuminated and, have level access over the threshold
öğrenmeye başla
oświetlony
threshold
All entrances should be illuminated and, have level access over the threshold
öğrenmeye başla
próg
Entrance doors
Entrance doors should have 300mm of clear space to the pull side, and clear minimum opening widths of 800mm or 825mm depending on the direction and width of approach.
öğrenmeye başla
Drzwi zewnętrzne
pull side
Entrance doors should have 300mm of clear space to the pull side, and clear minimum opening widths of 800mm or 825mm depending on the direction and width of approach
öğrenmeye başla
odstęp z boku
external landing
Main entrances should have weather protection and a level external landing.
öğrenmeye başla
Zewnętrzne podest
Communal
öğrenmeye başla
wspólne / społeczne
Evidence Summary
Summary of evidence on proposed housing design standards for the Examination in Public of the draft replacement London Plan
öğrenmeye başla
Podsumowanie dowodów

Yorum yapmak için giriş yapmalısınız.